Über den Betrieb
Users of electronic equipment and communications and information technology systems must keep their equipment in operation even though lightning strikes could cause momentary voltage spikes on power supply and data lines. Blitzschläge, die seit den ersten Untersuchungen von Benjamin Franklin im Jahr 1749 Gegenstand der Forschung sind, haben sich zu einer wachsenden Bedrohung für unsere von elektronischen Geräten abhängige Gesellschaft entwickelt. Lightning occurs between two oppositely charged zones in the atmosphere, typically between two thunderclouds or between a cloud and the ground. It can travel over several kilometers in successive jumps to the ground, with a guide flash first causing a highly ionized lightning channel. Only when this reaches the ground does the actual flash or main flash occur. Then a current of several tens of thousands of amperes flows through the ionized channel from the ground to the cloud or vice versa. FIG. 1 - Positively charged ice crystals are at the top of the thundercloud, negatively charged water droplets at the bottom. FIG. 2 - Negative charges in the guide flash first toward the ground, where charge redistribution occurs. FIG. 3 - The guide flash is met by a positive discharge from the ground. FIG. 4 - Charge carriers move between thundercloud and ground in the main flash. FIG. 5 - The lightning has exchanged charges between the cloud and the ground. The ground is now more negatively charged than before. At the time of discharge, a pulse current flows with a peak value between 1,000 and 200,000 amperes and a rise time of a few microseconds. The direct effects lead to damage to structural installations through mechanical damage or even a fire. The best protection is still provided by the classic lightning conductors or lightning protection systems, which are designed to 'capture' the leakage current and feed it to a specific point. The direct effects of a lightning strike in structural facilities hit their electrical and electronic systems in particular. High lightning currents lead to high potential rises and high voltage differences that can easily damage electrical equipment. The keraunic level indicates the number of thunderstorm days per year in a specific area or location. The keraunic level is subject to strong regional fluctuations and ranges from less than 1 in the Arctic and Antarctic to up to 180 near the equator. If the local keraunic levels are plotted on a map, lines of equal frequency, so-called isokerauns, can be drawn around areas of constant levels. Depending on this and other criteria of the risk analysis, the use of surge protection devices may be recommended or even mandatory. In order to test its products internally for standards compliance and to evolve toward greater reliability CITEL has several test sites (France, USA, China) equipped with : The G100K test generator in Reims (France) can produce exceptionally high impulse current of 100 kA and is used for testing structural lightning protection systems as well as Type 1 surge protectors. Since 1937, CITEL has been protecting equipment around the world from transient overvoltages caused by switching operations and lightning strikes. CITEL develops all critical protection solutions in-house. Our teams around the world take pride in helping to provide the market with a comprehensive range of surge protection products with our unique customer-focused service and quality. Unique, like our strategic vision, financial independence, international technical cooperation and strong individual commitment. This ambition guides our daily work. We take into account the specific needs, risks and applications of local markets and provide protection for low-voltage installations, communication networks, photovoltaic systems and LED lighting.
Branchen
Mehr Hersteller elektronischer Geräte in BochumGehört Ihnen dieser Betrieb?
Übernehmen Sie den Eintrag und pflegen Sie Ihre Angaben selbst.
Das ist mein BetriebDaten aus unserem Verzeichnis. Etwas stimmt nicht? Korrektur melden